I did an installation of Bitlocker Administration and Monitoring tool today in an Configuration Manager 2012 Sp1 environment with multiple Reporting Services points. When running the installation of MBAM 2 on the Configuration Manager 2012 server I ran into this issue:
“Setup was unable to verify prerequisites on the computer”
Error: Sequence contains more than one element.
The only useful thing in the log file was that the last thing it checked was the last thing it checked was:
Checking that the CM server is considered a primary site CM system.
Checking that the CM server is considered a primary site CM system.
Checking that the CM server has the Desired Configuration Management (DCM) agent enabled.
Checking that the CM server has the Hardware Inventory agent enabled.
Checking that CM has SQL Server Reporting Services (SSRS) integration
Checking SSRS user permissions.
Removing one of the Reporting Services Points solved the issue and the installation was successful.