To sum up the serial number reporting I have been working on at a customer. This post covers how to update the builtin report "Hardware 01A – Summary of computers in a specific collection", to display the serial number from the value inventoried from the BIOS instead of the value inventoried using System Enclosure. The reason for this change is that the Lenovo comptures as well as other vendors display a blank in value for the serial number in the report. Changing it to use the value already inventoried using the Win32_BIOS WMI provider displays the correct value.
The changes made to the report are highlighted in red, so you can modify the report instead of copying the whole report.
select distinct
v_R_System_Valid.ResourceID,
v_R_System_Valid.Netbios_Name0 AS [Computer Name],
v_R_System_Valid.Resource_Domain_OR_Workgr0 AS [Domain/Workgroup],
v_Site.SiteName as [SMS Site Name],
[Top Console User] = CASE
when (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 is NULL or v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 = ‘-1’)
then ‘Unknown’
Else v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0
End,
v_GS_OPERATING_SYSTEM.Caption0 AS [Operating System],
v_GS_OPERATING_SYSTEM.CSDVersion0 AS [Service Pack Level],
v_GS_PC_BIOS.SerialNumber0 AS [Serial Number],
v_GS_SYSTEM_ENCLOSURE_UNIQUE.SMBIOSAssetTag0 AS [Asset Tag],
v_GS_COMPUTER_SYSTEM.Manufacturer0 AS [Manufacturer],
v_GS_COMPUTER_SYSTEM.Model0 AS [Model],
v_GS_X86_PC_MEMORY.TotalPhysicalMemory0 AS [Memory (KBytes)],
v_GS_PROCESSOR.NormSpeed0 AS [Processor (GHz)],
(Select sum(Size0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and
v_FullCollectionMembership.CollectionID = @CollectionID) As [Disk Space (MB)],
(Select sum(v_GS_LOGICAL_DISK.FreeSpace0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and v_FullCollectionMembership.CollectionID = @CollectionID) As [Free Disk Space (MB)]
from v_R_System_Valid
inner join v_GS_OPERATING_SYSTEM on (v_GS_OPERATING_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
left join v_GS_SYSTEM_ENCLOSURE_UNIQUE on (v_GS_SYSTEM_ENCLOSURE_UNIQUE.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_COMPUTER_SYSTEM on (v_GS_COMPUTER_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PC_BIOS on (v_GS_PC_BIOS.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_X86_PC_MEMORY on (v_GS_X86_PC_MEMORY.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PROCESSOR on (v_GS_PROCESSOR.ResourceID = v_R_System_Valid.ResourceID)
inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_R_System_Valid.ResourceID)
left join v_Site on (v_FullCollectionMembership.SiteCode = v_Site.SiteCode)
inner join v_GS_LOGICAL_DISK on (v_GS_LOGICAL_DISK.ResourceID = v_R_System_Valid.ResourceID) and v_GS_LOGICAL_DISK.DeviceID0=SUBSTRING(v_GS_OPERATING_SYSTEM.WindowsDirectory0,1,2)
left join v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP on (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.ResourceID = v_R_System_Valid.ResourceID)
Where v_FullCollectionMembership.CollectionID = @CollectionID
Order by v_R_System_Valid.Netbios_Name0v_R_System_Valid.ResourceID,
v_R_System_Valid.Netbios_Name0 AS [Computer Name],
v_R_System_Valid.Resource_Domain_OR_Workgr0 AS [Domain/Workgroup],
v_Site.SiteName as [SMS Site Name],
[Top Console User] = CASE
when (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 is NULL or v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 = ‘-1’)
then ‘Unknown’
Else v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0
End,
v_GS_OPERATING_SYSTEM.Caption0 AS [Operating System],
v_GS_OPERATING_SYSTEM.CSDVersion0 AS [Service Pack Level],
v_GS_PC_BIOS.SerialNumber0 AS [Serial Number],
v_GS_SYSTEM_ENCLOSURE_UNIQUE.SMBIOSAssetTag0 AS [Asset Tag],
v_GS_COMPUTER_SYSTEM.Manufacturer0 AS [Manufacturer],
v_GS_COMPUTER_SYSTEM.Model0 AS [Model],
v_GS_X86_PC_MEMORY.TotalPhysicalMemory0 AS [Memory (KBytes)],
v_GS_PROCESSOR.NormSpeed0 AS [Processor (GHz)],
(Select sum(Size0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and
v_FullCollectionMembership.CollectionID = @CollectionID) As [Disk Space (MB)],
(Select sum(v_GS_LOGICAL_DISK.FreeSpace0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and v_FullCollectionMembership.CollectionID = @CollectionID) As [Free Disk Space (MB)]
from v_R_System_Valid
inner join v_GS_OPERATING_SYSTEM on (v_GS_OPERATING_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
left join v_GS_SYSTEM_ENCLOSURE_UNIQUE on (v_GS_SYSTEM_ENCLOSURE_UNIQUE.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_COMPUTER_SYSTEM on (v_GS_COMPUTER_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PC_BIOS on (v_GS_PC_BIOS.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_X86_PC_MEMORY on (v_GS_X86_PC_MEMORY.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PROCESSOR on (v_GS_PROCESSOR.ResourceID = v_R_System_Valid.ResourceID)
inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_R_System_Valid.ResourceID)
left join v_Site on (v_FullCollectionMembership.SiteCode = v_Site.SiteCode)
inner join v_GS_LOGICAL_DISK on (v_GS_LOGICAL_DISK.ResourceID = v_R_System_Valid.ResourceID) and v_GS_LOGICAL_DISK.DeviceID0=SUBSTRING(v_GS_OPERATING_SYSTEM.WindowsDirectory0,1,2)
left join v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP on (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.ResourceID = v_R_System_Valid.ResourceID)
Where v_FullCollectionMembership.CollectionID = @CollectionID
Order by v_R_System_Valid.Netbios_Name0 distinct
v_R_System_Valid.ResourceID,
v_R_System_Valid.Netbios_Name0 AS [Computer Name],
v_R_System_Valid.Resource_Domain_OR_Workgr0 AS [Domain/Workgroup],
v_Site.SiteName as [SMS Site Name],
[Top Console User] = CASE
when (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 is NULL or v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0 = ‘-1’)
then ‘Unknown’
Else v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.TopConsoleUser0
End,
v_GS_OPERATING_SYSTEM.Caption0 AS [Operating System],
v_GS_OPERATING_SYSTEM.CSDVersion0 AS [Service Pack Level],
v_GS_PC_BIOS.SerialNumber0 AS [Serial Number],
v_GS_SYSTEM_ENCLOSURE_UNIQUE.SMBIOSAssetTag0 AS [Asset Tag],
v_GS_COMPUTER_SYSTEM.Manufacturer0 AS [Manufacturer],
v_GS_COMPUTER_SYSTEM.Model0 AS [Model],
v_GS_X86_PC_MEMORY.TotalPhysicalMemory0 AS [Memory (KBytes)],
v_GS_PROCESSOR.NormSpeed0 AS [Processor (GHz)],
(Select sum(Size0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and
v_FullCollectionMembership.CollectionID = @CollectionID) As [Disk Space (MB)],
(Select sum(v_GS_LOGICAL_DISK.FreeSpace0)
from v_GS_LOGICAL_DISK inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_GS_LOGICAL_DISK.ResourceID )
where v_GS_LOGICAL_DISK.ResourceID =v_R_System_Valid.ResourceID and v_FullCollectionMembership.CollectionID = @CollectionID) As [Free Disk Space (MB)]
from v_R_System_Valid
inner join v_GS_OPERATING_SYSTEM on (v_GS_OPERATING_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
left join v_GS_SYSTEM_ENCLOSURE_UNIQUE on (v_GS_SYSTEM_ENCLOSURE_UNIQUE.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_COMPUTER_SYSTEM on (v_GS_COMPUTER_SYSTEM.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PC_BIOS on (v_GS_PC_BIOS.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_X86_PC_MEMORY on (v_GS_X86_PC_MEMORY.ResourceID = v_R_System_Valid.ResourceID)
inner join v_GS_PROCESSOR on (v_GS_PROCESSOR.ResourceID = v_R_System_Valid.ResourceID)
inner join v_FullCollectionMembership on (v_FullCollectionMembership.ResourceID = v_R_System_Valid.ResourceID)
left join v_Site on (v_FullCollectionMembership.SiteCode = v_Site.SiteCode)
inner join v_GS_LOGICAL_DISK on (v_GS_LOGICAL_DISK.ResourceID = v_R_System_Valid.ResourceID) and v_GS_LOGICAL_DISK.DeviceID0=SUBSTRING(v_GS_OPERATING_SYSTEM.WindowsDirectory0,1,2)
left join v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP on (v_GS_SYSTEM_CONSOLE_USAGE_MAXGROUP.ResourceID = v_R_System_Valid.ResourceID)
Where v_FullCollectionMembership.CollectionID = @CollectionID
Order by v_R_System_Valid.Netbios_Name0After This
Keep posting stuff like this i really like it
Use SCCM 2007 SP2. “incorrect syntax near the keyword as” returned. Any help is welcome.
Thx.
To sum up the serial number reporting I have been working on at a customer. This post covers how to update the builtin report “Hardware 01A – Summary of computers in a specific collection”, to display the serial number from the value inventoried from the BIOS instead of the value inventoried using System Enclosure. The reason for this change is that the Lenovo comptures as well as other vendors display a blank in value for the serial number in the report. Changing it to use the value already inventoried using the Win32_BIOS WMI provider displays the correct value.